Get a Quote
icon-address anqiu , china

welcome to visit us

The ultrafine pulverizer tells you what effect is for the low temperature!

  In the Chinese medicine industry, the ultrafine pulverizer exerts a unique role. So everyone knows what the design is, let's take a look at this lower crushing temperature for crushing drugs!

  The unique classification chamber and graded wheel, the gradular gear level, uniform, uniform, uniform, unique, unique, unique, no need to configure the screen, can granularize the product at low speed Classification; the circulating feed structure is strictly limited by "large particles" and avoids pulverizing, so the particle size distribution is narrow, the particle size is uniform; the grading wheel is classified, and the powder is difficult to sieve 150 mesh. . The ultra-fine pulverizer is low, and the phenomenon of "overshalting" is avoided. The pulverizing chamber does not produce excess heat. At the same time, the air inlet is provided in the pulverized chamber feed end (which can be connected if necessary). Due to the presence of the ventilation, the temperature that occurs at the time of pulverization is taken away, and the circulating water sleeve is added to the pulverizing casing to further reduce the temperature of the pulverized production. Fully closed negative pressure, powder does not take any leaks during the pulverization process, no environmental pollution, small noise; rounded design, easy to remove, easy to clean, easy to clean. How to maintain the ultrafine pulverizer: 1. During the production process, the temperature rise of the bearing must be often checked. When the temperature rise exceeds 50 ° C, it should be closed, and the reason is to rule out the fault. 2, when the new machine is running, the drive belt is easy to elongate, and should pay attention to adjust the appropriate looseness of the belt to ensure the work life of the belt. 3. If the loss case should be checked frequently, replace the quality and production volume in time. 4, blade, the bushing should often check the wear situation, if wear, the productivity decreases, and the particle size is replaced after the particle size is replaced. 5, the host and the grading flow bearing are lipid lubrication, using 2 special lipids, degrees 265-295.6, and the bearing changes period of 2000 hours, the amount of the filling of the grease is 1/2 of the space in the bearing cavity (upper Measurement) or 3/4 (lower test) Do not fill the grease too much or if the bearing temperature is too high. 7, the spiral feeder has changed the lipid period of 4,000 hours, and the calcium-based grease is added.